Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System

Product Details
Customization: Available
After-sales Service: Online Technical Support
Warranty: 1 Year
Still deciding? Get samples of US$ 130/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Fast Delivery
The supplier can deliver the goods within 15 days
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (25)
  • Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System
  • Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System
  • Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System
  • Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System
  • Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System
  • Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Certifications
  • Packaging & Shipping
  • Installation Instructions
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
XH-2000D
Application
Ventilator
Principle
Recuperative Heat Exchanger
Style
Plate Type
Material
Steel
Installation
Ceiling Easy Installation
Function
Ventilation
Air Flow
2000
Static Pressure
180 PA
Motor Power
500W
Power Supply
220V/380V/50Hz or Other
Logo
Support Customization
Package
Support Customization
Noise
Low
Size
1250*1000*450 mm
Type
Small Ceiling Series
Transport Package
Wooden Package
Specification
1100*850*410 mm
Trademark
Customized logo
Origin
China
HS Code
8415830000
Production Capacity
50000/Year

Packaging & Delivery

Package Size
125.00cm * 100.00cm * 45.00cm
Package Gross Weight
100.000kg

Product Description

Product Description

Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System
Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System
Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System
Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System
Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System
Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System
 

Product Parameters

Model Air volume  (m³/h) Static pressure  (Pa) Motor power  (W) Power supply  
XH-1500D 1500 160 360 220V/380V
XH-2000D 2000 180 500 220V/380V
XH-2500D 2500 200 900 220V/380V
XH-3000D 3000 240 1100 220V/380V
XH-4000D 4000 260 1500 380V
XH-5000D 5000 280 2600 380V
XH-6000D 6000 300 3000 380V
XH-8000D 8000 400 4400 380V
XH-10000D 10000 450 6000 380V
XH-12000D 12000 550 8000 380V
XH-15000D 15000 600 11000 380V

 

Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation SystemCeiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System

Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System
Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System

Certifications

 

Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System

Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System

Packaging & Shipping

Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System
Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System
Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System
Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System
Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System

Installation Instructions

 
AIR DUCT DESIGN REQUIREMENTS
To achieve the lowest wind resistance and noise in the designed air duct, the fresh air output port and the
host, the exhaust output port and the main machine between the muffler or canvas soft connection;
For ceiling machines, spring shock absorbers or rubber shock absorbers must be installed on the boom;
When indoor hidden hoisting, maintenance and maintenance openings must be reserved;
The main engine and the main duct should maintain a slope angle of 3 to 5 degrees, and the position of the
main engine should be slightly higher;
Metal ducts must be insulated;
PVC pipe, rubber bellows, aluminum foil asbestos tube, aluminum foil composite pipe itself has thermal
insulation performance and can be installed directly;
For the installation of the damper, the proximal end and the end of the main air duct and the branch pipe
junction must be installed at the air volume control valve, the middle of the piping system can use the air
flow deflector or air volume regulation;
The duct and the duct should be connected with a flange, and the connection flange should be gasketed
with a rubber seal;
Choose the position where the air outlet is opened, and the opening of the air outlet should be uniform in
principle to ensure that the fresh air volume and exhaust air volume in various places in the room can be
balanced
The air outlet is not easy to open in the following positions, the turn of the sub-pipe, the tail of the duct,
and the reducer of the duct
 

 

 

 

Company Profile

Ceiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation SystemCeiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation SystemCeiling Mounted Erv Hrv Remote Controller Residential Fresh Air Recuperative Ventilation System

FAQ

1.Q: Are you Trading Company or Factory:
    A:.  We are Trading Company and also Factory
 2.Q: What's your production ability for one month?
     A:We can product 10000 cubic meters one month.  .
 3.Q:  What's your MOQ?
     A:6 cubic meters.
 4.Q:What's your shipping port?
    A:Tianjin,shanghai or any port as your reqirement 
 5.Q: What's your Payment Terms?
    A:L/C,T/T,Western Union  


    

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now